Measurement per phase and outlet, switchable, network-capable and multifunctional
The BN7500 is an intelligent PDU (Power Distribution Unit) with a comprehensive range of functions. As with the BN7000, it enables professional energy and capacity management through network-capable measurements for each phase and outlet at PDU level, plus switching per outlet. In addition, measurement values for each outlet can be monitored. Two sensor ports support rack monitoring with optional temperature and air humidity sensors.
Thanks to its compact design (1U), installing the BN7500 is flexible and space-saving, and therefore enables optimised cabling and air flow in the server rack.
Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. Furthermore, the BN7500 can be integrated into third-party software systems via SNMP or Modbus TCP, for example. Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.
The following measurement values are displayed per phase and outlet on the illuminated display and in the integrated web server:
Current [A]
Neutral conductor current [A] for three-phase versions
Voltage [V]
Frequency [Hz]
Active power [kW]
Reactive power [kVar]
Apparent power [kVA]
Active energy [kWh]
Reactive energy [kVarh]
Apparent energy [kVAh]
Power factor
Furthermore, the flexible design of the PDU and different technology modules make a multitude of customised versions possible.
Optional technology modules:
Residual Current Monitoring (RCM type B) AC [mA] and DC [mA], Surge Protection Device (SPD), GPIO module, housing colour, temperature and air humidity sensors
This PDU is available as a 19" version or for vertical installation.
16 A / 230 V
16 A / 230 V
Outlets Gesamt
Stecker
Kabeltyp
Leitungsschutzschalter
Maße
16 A / 230 V
802.750216 A / 230 V
016 A / 230 V
CEE 16A16 A / 230 V
H05VV-F 3G 2,50 mm²16 A / 230 V
16 A / 230 V
1500 x 44 x 65 mm16 A / 230 V
802.750016 A / 230 V
016 A / 230 V
CEE 16A16 A / 230 V
H05VV-F 3G 2,50 mm²16 A / 230 V
16 A / 230 V
1234 x 44 x 65 mm16 A / 230 V / Residual Current Monitoring per supply cable
16 A / 230 V / Residual Current Monitoring per supply cable
Outlets Gesamt
Stecker
Kabeltyp
Leitungsschutzschalter
Maße
16 A / 230 V / Residual Current Monitoring per supply cable
802.753116 A / 230 V / Residual Current Monitoring per supply cable
016 A / 230 V / Residual Current Monitoring per supply cable
CEE 16A16 A / 230 V / Residual Current Monitoring per supply cable
H05VV-F 3G 2,50 mm²16 A / 230 V / Residual Current Monitoring per supply cable
16 A / 230 V / Residual Current Monitoring per supply cable
1500 x 44 x 65 mm16 A / 400 V
16 A / 400 V
Outlets Gesamt
Stecker
Kabeltyp
Leitungsschutzschalter
Maße
16 A / 400 V
802.750616 A / 400 V
016 A / 400 V
CEE 16A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1533 x 44 x 65 mm16 A / 400 V
802.750816 A / 400 V
016 A / 400 V
CEE 16A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1762 x 44 x 65 mm16 A / 400 V / Residual Current Monitoring per phase
16 A / 400 V / Residual Current Monitoring per phase
Outlets Gesamt
Stecker
Kabeltyp
Leitungsschutzschalter
Maße
16 A / 400 V / Residual Current Monitoring per phase
802.752116 A / 400 V / Residual Current Monitoring per phase
016 A / 400 V / Residual Current Monitoring per phase
CEE 16A16 A / 400 V / Residual Current Monitoring per phase
H05VV-F 5G 2,50 mm²16 A / 400 V / Residual Current Monitoring per phase
16 A / 400 V / Residual Current Monitoring per phase
1762 x 44 x 65 mm32 A / 230 V
32 A / 230 V
Outlets Gesamt
Stecker
Kabeltyp
Leitungsschutzschalter
Maße
32 A / 230 V
802.750132 A / 230 V
032 A / 230 V
CEE 32A32 A / 230 V
H05VV-F 3G 4,00 mm²32 A / 230 V
2 x C16A32 A / 230 V
1234 x 44 x 65 mm32 A / 230 V
802.752432 A / 230 V
032 A / 230 V
CEE 32A32 A / 230 V
H05VV-F 3G 4,00 mm²32 A / 230 V
2 x C16A32 A / 230 V
1533 x 44 x 65 mm32 A / 230 V / Residual Current Monitoring per supply cable
32 A / 230 V / Residual Current Monitoring per supply cable
Outlets Gesamt
Stecker
Kabeltyp
Leitungsschutzschalter
Maße
32 A / 230 V / Residual Current Monitoring per supply cable
802.753232 A / 230 V / Residual Current Monitoring per supply cable
032 A / 230 V / Residual Current Monitoring per supply cable
CEE 32A32 A / 230 V / Residual Current Monitoring per supply cable
H05VV-F 3G 4,00 mm²32 A / 230 V / Residual Current Monitoring per supply cable
2 x C16A32 A / 230 V / Residual Current Monitoring per supply cable
1234 x 44 x 65 mm32 A / 400 V
32 A / 400 V
Outlets Gesamt
Stecker
Kabeltyp
Leitungsschutzschalter
Maße
32 A / 400 V
802.751132 A / 400 V
032 A / 400 V
CEE 32A32 A / 400 V
H05VV-F 5G 4,00 mm²32 A / 400 V
6 x C16A32 A / 400 V
1817 x 44 x 65 mm32 A / 400 V
802.750932 A / 400 V
032 A / 400 V
CEE 32A32 A / 400 V
H05VV-F 5G 4,00 mm²32 A / 400 V
6 x C16A32 A / 400 V
1762 x 44 x 65 mm32 A / 400 V / Residual Current Monitoring per phase
32 A / 400 V / Residual Current Monitoring per phase
Outlets Gesamt
Stecker
Kabeltyp
Leitungsschutzschalter
Maße
32 A / 400 V / Residual Current Monitoring per phase
802.753032 A / 400 V / Residual Current Monitoring per phase
032 A / 400 V / Residual Current Monitoring per phase
CEE 32A32 A / 400 V / Residual Current Monitoring per phase
H05VV-F 5G 4,00 mm²32 A / 400 V / Residual Current Monitoring per phase
6 x C16A32 A / 400 V / Residual Current Monitoring per phase
1945 x 44 x 65 mmDo you need more information about our products and services? Please feel free to contact us.