The counterpart to the horizontal 19” PDU (Power Distribution Unit) – a PDU in a compact 1U size for installing vertically in the sides of server racks (ZeroU) The counterpart to the horizontal 19" PDU (Power Distribution Unit) – a PDU in a compact 1U size for installing vertically in the sides of server racks (ZeroU) and other applications in which IT devices are powered by country-specific outlets. The PDUs are reliable and durable thanks to their robust aluminium profile and high-quality components. Their modular design and the versatile function modules enable them to be set up to satisfy customised requirements. Furthermore, the high packing and power density ensure efficient power distribution.
Alternative versions with international outlets (C13/C19) are available on request.
16 A / 230 V
16 A / 230 V
Outlets Gesamt
Phase(n)
Stecker
Strom je Phase (A)
Kabeltyp
Leitungsschutzschalter
Maße
16 A / 230 V
333.012216 A / 230 V
016 A / 230 V
116 A / 230 V
CEE 7/716 A / 230 V
16 A16 A / 230 V
H05VV-F 3G 1,50 mm²16 A / 230 V
16 A / 230 V
208 x 44 x 47 mm16 A / 230 V
333.41316 A / 230 V
016 A / 230 V
116 A / 230 V
CEE 7/716 A / 230 V
16 A16 A / 230 V
H05VV-F 3G 1,50 mm²16 A / 230 V
16 A / 230 V
565 x 44 x 47 mm16 A / 230 V
333.41716 A / 230 V
016 A / 230 V
116 A / 230 V
CEE 7/716 A / 230 V
16 A16 A / 230 V
H05VV-F 3G 1,50 mm²16 A / 230 V
16 A / 230 V
208 x 44 x 47 mm16 A / 230 V / With surge protection
16 A / 230 V / With surge protection
Outlets Gesamt
Phase(n)
Stecker
Strom je Phase (A)
Kabeltyp
Leitungsschutzschalter
Maße
16 A / 230 V / With surge protection
800.233416 A / 230 V / With surge protection
016 A / 230 V / With surge protection
116 A / 230 V / With surge protection
CEE 7/716 A / 230 V / With surge protection
16 A16 A / 230 V / With surge protection
H05VV-F 3G 1,50 mm²16 A / 230 V / With surge protection
16 A / 230 V / With surge protection
608 x 44 x 47 mm16 A / 400 V
16 A / 400 V
Outlets Gesamt
Phase(n)
Stecker
Strom je Phase (A)
Kabeltyp
Leitungsschutzschalter
Maße
16 A / 400 V
800.145316 A / 400 V
016 A / 400 V
316 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1713 x 44 x 47 mm16 A / 400 V
800.228316 A / 400 V
016 A / 400 V
316 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1457 x 44 x 47 mm16 A / 400 V
800.233716 A / 400 V
016 A / 400 V
316 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
734 x 44 x 47 mm16 A / 400 V
800.233916 A / 400 V
016 A / 400 V
316 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1203 x 44 x 47 mm16 A / 400 V
800.234216 A / 400 V
016 A / 400 V
316 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1458 x 44 x 47 mm16 A / 400 V
800.010716 A / 400 V
016 A / 400 V
316 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
821 x 44 x 47 mm16 A / 400 V
800.010916 A / 400 V
016 A / 400 V
316 A / 400 V
CEE 16A16 A / 400 V
16 A16 A / 400 V
H05VV-F 5G 2,50 mm²16 A / 400 V
16 A / 400 V
821 x 44 x 47 mm16 A / 400 V
800.011316 A / 400 V
016 A / 400 V
316 A / 400 V
2 x WEF16 A / 400 V
16 A16 A / 400 V
H05VV-F 2 x 5G 2,50 mm²16 A / 400 V
16 A / 400 V
1840 x 44 x 47 mm32 A / 230 V / 50 Hz
32 A / 230 V / 50 Hz
Outlets Gesamt
Phase(n)
Stecker
Strom je Phase (A)
Kabeltyp
Leitungsschutzschalter
Maße
32 A / 230 V / 50 Hz
800.327132 A / 230 V / 50 Hz
032 A / 230 V / 50 Hz
132 A / 230 V / 50 Hz
Connection terminal32 A / 230 V / 50 Hz
32 A32 A / 230 V / 50 Hz
32 A / 230 V / 50 Hz
32 A / 230 V / 50 Hz
930 x 44 x 44 mm32 A / 230 V / 50 Hz
800.327232 A / 230 V / 50 Hz
032 A / 230 V / 50 Hz
132 A / 230 V / 50 Hz
Connection terminal32 A / 230 V / 50 Hz
32 A32 A / 230 V / 50 Hz
32 A / 230 V / 50 Hz
32 A / 230 V / 50 Hz
930 x 44 x 44 mm32 A / 230 V / 50 Hz
800.338432 A / 230 V / 50 Hz
032 A / 230 V / 50 Hz
132 A / 230 V / 50 Hz
Connection terminal32 A / 230 V / 50 Hz
32 A32 A / 230 V / 50 Hz
32 A / 230 V / 50 Hz
32 A / 230 V / 50 Hz
955 x 44 x 44 mm32 A / 230 V / 50 Hz
800.338532 A / 230 V / 50 Hz
032 A / 230 V / 50 Hz
132 A / 230 V / 50 Hz
Connection terminal32 A / 230 V / 50 Hz
32 A32 A / 230 V / 50 Hz
32 A / 230 V / 50 Hz
32 A / 230 V / 50 Hz
955 x 44 x 44 mm32 A / 400 V
32 A / 400 V
Outlets Gesamt
Phase(n)
Stecker
Strom je Phase (A)
Kabeltyp
Leitungsschutzschalter
Maße
32 A / 400 V
800.234032 A / 400 V
032 A / 400 V
332 A / 400 V
CEE 32A32 A / 400 V
32 A32 A / 400 V
H05VV-F 5G 4,00 mm²32 A / 400 V
6 x C16A32 A / 400 V
1586 x 44 x 47 mmMit Überspannungsschutz | Netz- und Frequenzfilter
Mit Überspannungsschutz | Netz- und Frequenzfilter
Outlets Gesamt
Phase(n)
Stecker
Strom je Phase (A)
Kabeltyp
Leitungsschutzschalter
Maße
Mit Überspannungsschutz | Netz- und Frequenzfilter
800.2631Mit Überspannungsschutz | Netz- und Frequenzfilter
0Mit Überspannungsschutz | Netz- und Frequenzfilter
1Mit Überspannungsschutz | Netz- und Frequenzfilter
CCC 3-hole 16AMit Überspannungsschutz | Netz- und Frequenzfilter
10 AMit Überspannungsschutz | Netz- und Frequenzfilter
RVV 3G 1,5 mm²Mit Überspannungsschutz | Netz- und Frequenzfilter
Mit Überspannungsschutz | Netz- und Frequenzfilter
777 x 44 x 44 mm